CT Scan of the six-armed brittle star Ophiactis hex (Echinodermata: Ophiuroidea) – Supplementary material to Thuy et al. (2024): "Fossil evidence for the ancient link between clonal fragmentation, six-fold symmetry and an epizoic lifestyle in asterozoan echinoderms"
DOI: | https://doi.org/10.57756/5qej7m |
---|---|
Creator(s): |
|
Publication date: | 18 Apr 2024 |
Publisher: | Naturhistorisches Museum Wien (NHMW) |
Collections: | Central Research Laboratories , Geology & Palaeontology |
Instrument: | YXLON FF35 CT |
Resource type: | Dataset |
Specimen: | SMNS 70508 |
License: |
CC BY 4.0 International |
Tags: | Ct-scan Holotype Type material |
Countries: | Germany |
Chronology: | Kimmeridgian |
Taxa: | Ophiuroidea |
Share: |
|
Abstract
MicroCT scan of a the holoype (specimen SMNS 70508) of the new species Ophiactis hex Thuy et al., 2024 (Echinodermata: Ophiuroidea: Ophiactidae) from the Nusplingen Quarry on top of Westerberg hill, Nusplingen, Germany; Nusplingen Lithographic Limestone (Nusplingen Formation), Beckeri Zone, Ulmense Subzone, late Kimmeridgian, Late Jurassic.the in the collection of the Palaeontology Department, State Museum of Natural History Stuttgart.
Usage Notes
System: YXLON FF35 CT at the NHM Vienna, Austria
Detector: Perkin Elmer Y.Panel 4343 CT
Detail scan:
Beam: FXE Transmission beam
Filter: 0.2 mm Copper
Scan Parameters: 45 kV, 110 µA, 2000 ms exposure time, 1x1 binning, 3600 projection images
Isotropic voxel size: 7.1 µm
Overview scan:
Beam: FXE Transmission beam
Filter: 0.2 mm Copper
Scan Parameters: 65 kV, 165 µA, 2000 ms exposure time, 1x1 binning, 1800 projection images
Isotropic voxel size: 13.1 µm
Publications
Thuy, B., Numberger-Thuy, L.D., Härer, J., Kroh, A., Winkler, V. & Schweigert, G. (submitted) Fossil evidence for the ancient link between clonal fragmentation, six-fold symmetry and an epizoic lifestyle in asterozoan echinoderms. Proceedings of the Royal Society B
Downloads
File | Description | Size |
---|---|---|
SMNS-70508-Ophiactis-hex-fossil_ReconInfos.xml | Reconstruction parameters of the overview microCT scan of Ophiactis hex (SMNS 70508) | 0 MB |
SMNS-70508-Ophiactis-hex-fossil_ScanInfos.xml | Scanning parameters of the overview microCT scan of Ophiactis hex (SMNS 70508) | 0.01 MB |
SMNS-70508-Ophiactis-hex-fossil_TIF.zip | TIFF image stack of the overview microCT scan of Ophiactis hex (SMNS 70508) | 5073.16 MB |
SMNS-70508-Ophiactis-hex-fossil-detail_ReconInfos.xml | Reconstruction parameters of the detail microCT scan of Ophiactis hex (SMNS 70508) | 0 MB |
SMNS-70508-Ophiactis-hex-fossil-detail_ScanInfos.xml | Scanning parameters of the detail microCT scan of Ophiactis hex (SMNS 70508) | 0.01 MB |
SMNS-70508-Ophiactis-hex-fossil-detail_TIF.zip | TIFF image stack of the detail microCT scan of Ophiactis hex (SMNS 70508) | 9396.96 MB |